Product Information

Kingspan TR22, from the Thermaroof Range ...

Kingspan Thermaroof TR22 insulation beneath fully bonded built-up felt and insulated balconies.

Kingspan Thermaroof™TR22 is designed for use with waterproofed with mastic asphalt with a porous concrete insulation beneath fully bonded built-up felt and insulated balconies waterproofed with mastic asphalt with a porous concrete promenade tile overlay promenade tile overlay.
Kingspan TR22 Thermaroof  insulation insulation beneath fully bonded built-up felt and insulated balconies waterproofed with mastic asphalt with a porous concrete promenade tile overlay promenade tile overlay and beneath fully bonded built-up felt and insulated balconies waterproofed with mastic asphalt with a porous concrete

Benefits

High performance rigid urethane insulation – thermal conductivity 0.026- 0.027 W/mK
Uniquely laminated to cork using a patented manufacturing process
Glass tissue armature reinforcement increases tensile strength and stability
No requirement for a 3Gventilating layer Offers good resistance to foot traffic
Available in a tapered version Resistant to the passage of water vapour
Easy to handle and install Ideal for new build and refurbishment
Non–deleterious material
CFC/HCFC–free with zero Ozone Depletion Potential (ODP)

Applications

Kingspan Thermaroof TR22 insulation beneath fully bonded built-up felt and insulated balconies waterproofed with mastic asphalt with a porous concrete insulation beneath fully bonded built-up felt and insulated balconies waterproofed with mastic asphalt with a porous concrete promenade tile overlay promenade tile overlay.

Kingspan TR22 Board Sizes and Values

Available in in the standard size of 1200mm wide by 2400mm long, and in the following thicknesses ...

Product

R Value (mK/W)

Thermal Conductivity (W/mK)

U Value (W/m²K)

Compressive strength (kPa)

Water vapour resistance (MNs/g)

Reaction to fire

BS 476–3: 1958

TR22 100mm

3.55

0.026

0.13

³ 150

> 15

FAA Rating

Note:
R-Value = Thermal Resistance; Thermal Conductivity = Lambda Value; U-Value = Thermal Transmittance Co-efficient; Compressive strength = kiloPascals; Vapour resistance = MegaNewton seconds per gram.

Technical Specifications Kingspan TR21 BBA Certificate

Kingspan Thermaroof™TR22 roof insulation comprises a CFC/HCFC–free rigid urethane insulation and 20 mm thick cork facing autohesively bonded to the insulation core with armature during manufacture to the highest standards under quality control systems approved to BS EN ISO 9001: 2000 / I.S. EN ISO 9001: 2000 by Kingspan Insulation Limited and shall be applied in accordance with the instructions issued by them.

Falls

The fall on a flat roof should be smooth and steep enough to prevent the formation of rainwater pools. To ensure adequate drainage, BS 6229: 2003 (Flat roofs with continuously supported coverings. Code of practice), recommends uniform gradients of not less than 1 in 80. However, because of building settlement, it can be advisable to ‘design in’ even greater falls. These can be provided by the use of Kingspan Insulation Tapered Roofing System.

Tapered Roofing

Kingspan Thermaroof™TR22is also available in a tapered version (Kingspan®TT42), comprising a high performance CFC/HCFC–free rigid urethane core autohesively bonded to an upper facing of cork roof board and a lower facing of glass reinforced perforated cellulose during manufacture. Further details on the Kingspan Thermataper®System and a complete design service are available from the Kingspan Insulation Tapered Roofing Department (see rear cover) who should be consulted as early as possible in the process of roof design in order that they may offer the benefit of their considerable experience to the design team.

Cold Bridging

Reasonable provision must be made to limit the effects of cold bridging. The design should ensure that roof–light or ventilator kerbs etc. are always insulated to a similar standard as the general roof area. A 25 mm thick insulation up stand of at least150 mm should be used around the perimeter of the roof on the internal facade of the parapet. The exposed face of the insulation must be lined with 20 mm exterior grade plywood prior to the application of the waterproofing layer. Wall insulation should also be carried up into the parapet creating an ‘overlap’of insulation. Please contact the Kingspan Insulation Technical Service Department for further advice.

Water Vapour Control

Kingspan Thermaroof™TR22 should be installed over separate vapour control layer. A minimum vapour control layer should consist of a coated roofing felt complying with BS 747: 2000 Type 3B, or any appropriate metal–cored vapour control layer. Allowance should be made for the adequate bonding of the vapour control layer to the deck so as to provide a suitable surface for Kingspan Thermaroof™TR22to be laid upon, and sufficient resistance to wind up–lift (see ‘Wind Loading’). Metal decks and concrete decks should be primed prior to the application of the hot bitumen used to bond the vapour control layer to the deck.

Roof Loading

Depending on the chosen waterproofing system, Kingspan Thermaroof™TR22is suitable for use on access roof decks subject to limited foot traffic. Where continuous or excessive loadings are liable to occur it is recommended that the roof surface is protected by promenade tiles. The roof should be adequately protected when building works are being carried out on or over the roof surface. This is best achieved by close boarding. The completed roof must not be used for the storage of heavy building components such as bricks or air conditioning equipment.

Spanning on Metal Decks

The designer’s attention is drawn to the requirement that insulation boards comply with the minimum thicknesses shown in the table below, when used over metal decks with trough openings as shown.
Trough Opening ≤75mm - Minimum Insulant Thickness 25mm
Trough Opening 76–100mm - Minimum Insulant Thickness 30mm
Trough Opening 101–125mm - Minimum Insulant Thickness 35mm
Trough Opening 126–150mm - Minimum Insulant Thickness 40mm
Trough Opening 151–175mm - Minimum Insulant Thickness 45mm
Trough Opening 176–200mm - Minimum Insulant Thickness 50mm

Vapour Control

Layer Metal decks and concrete decks should be primed in accordance with the appropriate manufacturers instructions prior to the application of the hot bitumen or suitable alternative proprietary adhesive system used to bond the vapour control layer to the deck. The specified vapour control layer should be continued 250 mm past the insulation abutting the parapet and sealed.

Fixing over Metal Decks

On metal decks, Kingspan Thermaroof™TR22should be laid into hot bitumen (max. temperature 240°C) mopped or poured over the vapour control layer. The boards should be laid break–bonded, either with the long edges at right angles to the trough openings or diagonally across the corrugation line .Whichever system is chosen, care must be taken to ensure that all joints are supported by the deck. The joints should be lightly butted.

Fixing over Plywood Decks

Kingspan Thermaroof™TR22should be fully bedded in hot bitumen or with the use of suitable alternative proprietary adhesive systems. However, advice should be sought from the appropriate manufacturer of the adhesive system for their recommendations on the correct procedure for application rates and application temperatures over a continuous vapour control layer, which has been nailed or bonded to the deck with laps at the side and end sealed with either the use of hot bitumen or one the alternative proprietary adhesive systems as detailed previously. The boards should be laid break–bonded,either with the long edges at right angles to the edge or diagonally across the roof. Joints should be lightly butted.

Fixing over Concrete Decks

Concrete decks should be clean, dry, without large projections,steps or gaps, and should be graded to allow correct falls to all rainwater outlets. To ensure an adequate bond between the vapour control layer and the concrete deck, the concrete or screeded surface should be suitably primed, in accordance with the specified manufacturer’s instructions. The vapour control layer should be fully bonded to the deck and similarly the Kingspan Thermaroof™TR22to the vapour control layer by laying into hot bitumen mopped or poured over the vapour control layer. The boards should be laid break–bonded with all joints lightly butted. Fixing over Plywood Decks Kingspan Thermaroof™TR22should be fully bedded in hot bitumen over a continuous vapour control layer which has been nailed or bonded to the deck with laps at the side and end sealed with hot bitumen. The boards should be laid break–bonded, either with the long edges at right angles to the edge or diagonally across the roof. Joints should be lightly butted.

Fixing over Tongue & Groove Decks

On timber tongue and groove decks, the vapour control layer should be nailed. During the laying of Kingspan Thermaroof™TR22the nail heads will become sealed in hot bitumen to the vapour control layer by the subsequent bonding of the roof board. The Kingspan Thermaroof™TR22is then applied as described under plywood decks.

Fixing over Woodwool Decks

Woodwool decks should be clean and free of large projections, steps or gaps and should be graded to allow correct falls to all rainwater outlets. Kingspan Thermaroof™TR22should be fully bedded in hot bitumen over a continuous vapour control layer. Boards should be laid diagonally across the roof, or with their long edges at right angles to the slabs. Board joints should not coincide with those of the slabs. The boards should be laid break–bonded, either with the long edges at right angles to the edge or diagonally across the roof. Joints should be lightly butted. Board joints should not coincide with those of the slabs.

Fixing Two Layer Systems

In situations where two layers of insulation are required, both layers of insulation should be installed in the same manner, which varies according to the deck type (as detailed above). In all cases, the two layers should be horizontally offset relative to each other so that no two board joints in the two layers coincide with each other.

Pitched Or Sloping Roofs

Any provisions for mechanical fixing of the waterproofing to prevent slippage of the cap sheet, should be made prior to the application of Kingspan Thermaroof™TR22.

Mechanical Fixings

The number of mechanical fixings required to fix Kingspan Thermaroof™TR22will vary with the geographical location of the building, the topographical data, and the height and width of the roof concerned.Each fixing should incorporate a square or circular plate washer (50 mm x 50 mm or 50 mm diameter).A minimum 4 No. fixings should be placed within the individual board area and be sited > 50 mm and < 150 mm from the edges and corners of the board giving a minimum fixing rate of5.55 fixings per square metre: (1.2 x 0.6 m boards).

Reflective coatings

Bitumen based built up waterproofing systems laid over Kingspan Thermaroof™TR22 should always incorporate a solar reflective layer such as chippings or specialist coatings.

Daily Working Practice

At the completion of each day’s work, or whenever work is interrupted for extended periods of time, a night joint must be made in order to prevent water penetration of the roof construction.

Cutting

Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Ensure accurate trimming to achieve close–butting joints and continuity of insulation.

Downloads - select from drop-down menu below


Manufacturer's Contact Details

Kingspan Insulation Limited
Pembridge, Leominster, Herefordshire, HR6 9LA
Kingspan Technical Advisory. Tel: 0870 850 8333
Fax: 01544 387 278 - techline.uk@insulation.kingspan.com

This page was last updated: Wednesday, February 1, 2012

Kingspan TR22 from as little as £23.02m² - £16.57 per board

Prices effective on all deliveries from September 30, 2010, onwards.

Select required items by ticking the appropriate tick-boxes
Select the "Go to Shopping Cart - Add Quantities" button,
then add the required quantities on the shopping cart page.

 

Due to distribution logistics and costs, all Kingspan orders must achieve a minimum level of £250 when ordered with additional items that also meet this £250 minimum order level threshold.

 

Kingspan TR22 100mm, 3x0.6x1.2m = 2.16m² -

Not presently available. Please telephone for information

1 plus packs @ £25.99 per m² = £56.13
11 plus packs @ £25.76 per m² = £55.64
22 plus packs @ £25.54 per m² = £55.15
33 plus packs @ £25.32 per m² = £54.67
45 plus packs @ £25.09 per m² = £54.18
56 plus packs @ £24.86 per m² = £53.69

Aluminised Tape, 100mm x 45m = 45lm

1 plus rolls = £6.45
5 plus rolls = £6.35
10 plus rolls = £6.25
15 plus rolls = £6.15
20 plus rolls = £6.04
25 plus rolls = £5.94

 

Insulation Online Limited

27 Massetts Road, Horley, Surrey, RH6 7DQ

Email: enquiries@insulation-online.com

insulation-online.com - £500.00+ orders/large vehicle access
just-heating.com - electric central heating, boilers, radiators
just-rooflights.com - rigid tube light pipes / sky light tunnels
just-insulation.com - DIY specialists and small builders

Search

All information is extracted from that provided by the manufacturer, and links to their technical literature are provided above. Please contact the manufacturer for details beyond the scope of this web site.

Select the products that you require, by ticking the appropriate boxes, then click the 'Add to Cart' button to add quantities.