Celotex TB4012 12mm, 1.2x2.4m = 2.88m²
1 plus boards @ £3.01 per m² = £8.65 (£10.38 Inc-VAT) |
36 plus boards @ £2.98 per m² = £8.57 (£10.29 Inc-VAT) |
71 plus boards @ £2.96 per m² = £8.50 (£10.20 Inc-VAT) |
107 plus boards @ £2.93 per m² = £8.42 (£10.11 Inc-VAT) |
144 plus boards @ £2.90 per m² = £8.35 (£10.02 Inc-VAT) |
182 plus boards @ £2.88 per m² = £8.27 (£9.93 Inc-VAT) |
Celotex TB4020 20mm, 1.2x2.4m = 2.88m²
1 plus boards @ £3.39 per m² = £9.76 (£11.72 Inc-VAT) |
31 plus boards @ £3.37 per m² = £9.68 (£11.62 Inc-VAT) |
63 plus boards @ £3.33 per m² = £9.59 (£11.51 Inc-VAT) |
95 plus boards @ £3.31 per m² = £9.51 (£11.42 Inc-VAT) |
128 plus boards @ £3.28 per m² = £9.42 (£11.31 Inc-VAT) |
161 plus boards @ £3.25 per m² = £9.34 (£11.21 Inc-VAT) |
Celotex TB4025 25mm, 1.2x2.4m = 2.88m²
1 plus boards @ £3.99 per m² = £11.47 (£13.77 Inc-VAT) |
27 plus boards @ £3.95 per m² = £11.37 (£13.65 Inc-VAT) |
54 plus boards @ £3.92 per m² = £11.27 (£13.53 Inc-VAT) |
81 plus boards @ £3.88 per m² = £11.17 (£13.41 Inc-VAT) |
109 plus boards @ £3.85 per m² = £11.07 (£13.29 Inc-VAT) |
137 plus boards @ £3.81 per m² = £10.97 (£13.17 Inc-VAT) |
Celotex TB4030 30mm, 1.2x2.4m = 2.88m²
1 plus boards @ £4.33 per m² = £12.47 (£14.97 Inc-VAT) |
25 plus boards @ £4.30 per m² = £12.36 (£14.84 Inc-VAT) |
49 plus boards @ £4.26 per m² = £12.25 (£14.70 Inc-VAT) |
75 plus boards @ £4.22 per m² = £12.14 (£14.57 Inc-VAT) |
100 plus boards @ £4.19 per m² = £12.04 (£14.45 Inc-VAT) |
126 plus boards @ £4.15 per m² = £11.93 (£14.32 Inc-VAT) |
Celotex TB4035 35mm, 1.2x2.4m = 2.88m²
1 plus boards @ £4.70 per m² = £13.51 (£16.22 Inc-VAT) |
23 plus boards @ £4.65 per m² = £13.39 (£16.07 Inc-VAT) |
46 plus boards @ £4.61 per m² = £13.27 (£15.93 Inc-VAT) |
69 plus boards @ £4.57 per m² = £13.16 (£15.80 Inc-VAT) |
93 plus boards @ £4.53 per m² = £13.04 (£15.65 Inc-VAT) |
117 plus boards @ £4.49 per m² = £12.92 (£15.51 Inc-VAT) |
Celotex TB4040 40mm, 1.2x2.4m = 2.88m²
1 plus boards @ £5.08 per m² = £14.62 (£17.55 Inc-VAT) |
21 plus boards @ £5.04 per m² = £14.49 (£17.39 Inc-VAT) |
42 plus boards @ £4.99 per m² = £14.37 (£17.25 Inc-VAT) |
64 plus boards @ £4.95 per m² = £14.24 (£17.09 Inc-VAT) |
86 plus boards @ £4.90 per m² = £14.11 (£16.94 Inc-VAT) |
108 plus boards @ £4.86 per m² = £13.98 (£16.78 Inc-VAT) |
Celotex TB4045 45mm, 1.2x2.4m = 2.88m²
1 plus boards @ £5.68 per m² = £16.33 (£19.60 Inc-VAT) |
19 plus boards @ £5.62 per m² = £16.18 (£19.42 Inc-VAT) |
38 plus boards @ £5.57 per m² = £16.04 (£19.25 Inc-VAT) |
57 plus boards @ £5.53 per m² = £15.90 (£19.08 Inc-VAT) |
77 plus boards @ £5.48 per m² = £15.76 (£18.92 Inc-VAT) |
97 plus boards @ £5.43 per m² = £15.62 (£18.75 Inc-VAT) |
Celotex Insulation Clips (bag of 100)
1 plus bags @ £10.20 (£12.24 Inc-VAT) |
2 plus bags @ £10.12 (£12.15 Inc-VAT) |
3 plus bags @ £10.03 (£12.04 Inc-VAT) |
4 plus bags @ £9.95 (£11.94 Inc-VAT) |
5 plus bags @ £9.86 (£11.84 Inc-VAT) |
6 plus bags @ £9.78 (£11.74 Inc-VAT) |
Aluminised Tape, 100mm x 45m = 45lm
1 plus rolls @ £0.17 per lm = £7.42 (£8.91 Inc-VAT) |
5 plus rolls @ £0.17 per lm = £7.33 (£8.80 Inc-VAT) |
10 plus rolls @ £0.17 per lm = £7.24 (£8.69 Inc-VAT) |
15 plus rolls @ £0.16 per lm = £7.14 (£8.57 Inc-VAT) |
20 plus rolls @ £0.16 per lm = £7.05 (£8.46 Inc-VAT) |
25 plus rolls @ £0.16 per lm = £6.96 (£8.36 Inc-VAT) |
Insulation Online Limited
27 Massetts Road, Horley,Surrey, RH6 7DQ
insulation-online.com - £500.00+ orders/large vehicle access
just-rooflights.com - rigid tube light pipes / sky light tunnels
just-insulation.com - DIY specialists and small builders
- Basket Items =
Basket Total =
Including VAT=
Celotex T-Break - Celotex TB4000 Range
(previously TB3000) ...
Combats local thermal bridging and provides reliable long-term energy savings
A multi-purpose insulation board developed to provide simple solutions for overcoming localised thermal bridges. With low emissivity foil facings, TB4000 is manufactured from rigid polyisocyanurate (PIR) using a blend of blowing agents that have zero ozone depletion potential (zero ODP) and a low global warming impact.
Benefits
The T-Break name stems from the design function of the range; which is to provide simple solutions to overcome localised thermal bridges. Celotex is unique in being able to offer boards as thin as 12 mm to the market for this purpose.
TB4000 Range products have similar characteristics to the Celotex Tuff-R range but with an un-reinforced core foam.
Applications
Celotex TB4000 can be specified for use in a variety of applications including ... Pitched Roofs, Flat Roofs, Solid Masonry Walls, Timber Framed & Steel Framed systems, and Floors.
Celotex T-Break Board Sizes and Values
Available in a standard board size of 1200 x 2400mm with the following specifications ...
Celotex TB4000 T-Break (supersedes TB3000 Range) Technical Data |
Product Code |
Board dimensions (width) x (length) = (m²) |
Thickness (mm) |
R-value (m2K/W) |
U-Value (W/m²K) |
Weight (kg/m2) |
Board / Pack weight (kg) |
Celotex TB4012 |
1.2x2.4 = 2.88m² |
12 |
0.50 |
2.00 |
0.50 |
1.44 |
Celotex TB4020 |
1.2x2.4 = 2.88m² |
20 |
0.90 |
1.11 |
0.72 |
2.07 |
Celotex TB4025 |
1.2x2.4 = 2.88m² |
25 |
1.10 |
0.91 |
0.85 |
2.45 |
Celotex TB4030 |
1.2x2.4 = 2.88m² |
30 |
1.35 |
0.74 |
0.98 |
2.82 |
Celotex TB4035 |
1.2x2.4 = 2.88m² |
35 |
1.55 |
0.65 |
1.11 |
3.20 |
Celotex TB4040 |
1.2x2.4 = 2.88m² |
40 |
1.80 |
0.56 |
1.26 |
3.63 |
Celotex TB4045 |
1.2x2.4 = 2.88m² |
45 |
2.00 |
0.50 |
1.40 |
4.03 |
Thermal conductivity / Lambda value (W/mK) = 0.022: R-Value = Thermal Resistance; U-Value = Thermal Transmittance Co-efficient; Compresive strength (kPa) = ≥ 120: Dimensional stability = DS(TH)8; Water vapour restistance (MNs/g) = > 150: Surface spread of flame = Class 1 |

Technical Specification
Please see the Celotex Tuff-R GA4000 page for details of the technical specifications of this thinner version of that product.
Where Celotex T-Break TB4000 should be used
This thinner version can be used in any rafter or joist application where there is the need to minimize thermal bridging and improve U-Values.
Thermal Bridging
To understand thermal bridging more thoroughly, this is where a (often structural) member with poorer thermal performance has a lower thermal resistance. This is a matter of degree and cannot be avoided just minimised. Therefore, there is a need to compensate by increasing the level of general insulation.
To gain a more formal understanding, we quote ...
Surface condensation – thermal bridging Thermal bridging occurs when the continuity of the building fabric is broken by the penetration of an element allowing a significantly higher heat loss than its surroundings.
These ‘bridges’ commonly occur around openings such as lintels, jambs and sills and at wall/roof junctions, wall/floor junctions and where internal walls penetrate the outer fabric.
Thermal bridges provide a ready passage of heat transfer to the outside air and allow a heat flow entirely disproportionate to their surface area resulting in excessive heat losses.
Condensation may occur on the inner surfaces that can damage the dwelling or threaten the health of the occupants.
To minimise the risk of condensation on any inner surface, cold bridging at a floor, wall, roof or other building element should be avoided.
Detailing should be in accordance with the recommendations in Section 8 of BS 5250: 2002 [ CIS link: BS 5250:2002. (the code of practice for control of condensation in buildings + AMD 16119).
Also, to maintain an adequate internal surface temperature and thus minimise the risk of surface condensation, it is recommended that the thermal transmittance (U-value) of any part and at any point of the external fabric does not exceed 1.2 W/m2K.
U-Value - a definition
U-value (or thermal transmittance co-efficient) is a measure of how much heat will pass through one square metre of a structure when the temperatures on either side of the structure differ by 1 degree Celsius (expressed in W/m2K)
Please contact manufacturer directly for detailed product information, U-Value calculations, et cetera.
Contact information at the top right of this page. Architects, Designers, Surveyors, and other professionals, should contact the manufacturers directly for technical information beyond the scope and content of this web site.
| | | | | | | | |